Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
deltaww infrasuite device master vulnerabilities and exploits
(subscribe to this query)
9.8
CVSSv3
CVE-2023-39226
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated malicious user to execute arbitrary code through a single UDP packet.
Deltaww Infrasuite Device Master 1.0.7
9.8
CVSSv3
CVE-2023-47207
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated malicious user to execute code with local administrator privileges.
Deltaww Infrasuite Device Master 1.0.7
9.8
CVSSv3
CVE-2023-30765
?Delta Electronics InfraSuite Device Master versions before 1.0.7 contain improper access controls that could allow an malicious user to alter privilege management configurations, resulting in privilege escalation.
Deltaww Infrasuite Device Master
1 Github repository
9.8
CVSSv3
CVE-2023-34347
?Delta Electronics InfraSuite Device Master versions before 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2023-1140
Delta Electronics InfraSuite Device Master versions before 1.0.5 contain a vulnerability that could allow an malicious user to achieve unauthenticated remote code execution in the context of an administrator.
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2023-1142
In Delta Electronics InfraSuite Device Master versions before 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2023-1133
Delta Electronics InfraSuite Device Master versions before 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated mal...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-40202
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without...
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41772
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
Deltaww Infrasuite Device Master
9.8
CVSSv3
CVE-2022-41779
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, ...
Deltaww Infrasuite Device Master
CVSSv3
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-27322
cross-site request forgery
unauthorized
CVE-2024-33925
reflected XSS
CVE-2023-51580
CVE-2023-51579
CVE-2015-2051
CVE-2023-51609
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started
1
2
3
4
NEXT »